You turn the shower on, the bathroom goes dark and the RCD on your consumer unit has dropped. An electric shower tripping the RCD is one of the most common calls we get from homeowners across Lincolnshire, especially in the colder months when showers work hardest. It is easy to treat it as a nuisance, but it is your electrical system telling you something is wrong.
This guide explains what the RCD is doing, the usual causes, what you can safely check yourself and when it is time to call an electrician.
Table of Contents
What the RCD is actually doing
An RCD (residual current device) constantly compares the current flowing out along the live conductor with the current coming back along the neutral. If some of it is escaping, for example through water, a damaged component or a person, the two no longer match and the RCD switches off in a fraction of a second. Most domestic RCDs trip at 30mA, a tiny amount of current, which is why they are so good at preventing electric shocks.
It is worth knowing the difference between an RCD and an MCB (the smaller circuit breakers). If only the shower’s MCB switches off, the circuit is usually overloaded or has a short circuit. If the RCD trips, something is leaking current to earth. Our guide to a power cut or tripped switch explains how to tell which has gone.
Common causes of an electric shower tripping the RCD
Electric showers draw a large current and mix electricity with water in a small space, so a few faults come up again and again:
- Water getting into the shower unit. A cracked cover, perished seal or loose fixing can let water reach the terminals or circuit board. This is the most common cause we find.
- A failing heating element. As elements age, their insulation breaks down and they start to leak current, often only once they are hot.
- Limescale build-up. Lincolnshire has hard water in many areas. Scale makes the element run hotter, which speeds up wear and can lead to leakage.
- Burnt or loose connections. Showers put a heavy load through the pull-cord switch or isolator and the terminals. Loose connections overheat, and scorched switches are a common find.
- Damaged or poorly installed cable. A cable that has been nicked, crushed or run through a wet area can leak to earth.
- Leakage from other circuits. On older split-load consumer units, one RCD can protect several circuits. Small amounts of leakage from appliances add up, and switching on the shower can be the last straw.
- A faulty RCD. Less often, the RCD itself is worn out and trips too easily.
What you can safely check yourself
There is not much a homeowner should do inside a shower, but you can gather useful clues for your electrician:
- Switch the shower off at its isolator or pull-cord before doing anything else.
- Look for water leaking from the bottom or sides of the unit, condensation behind the cover, or scorch marks or a burning smell at the switch.
- Note when it trips: straight away, only after a few minutes of hot water, or only when other appliances are on.
- Try resetting the RCD with the shower isolated. If it now stays on, the shower circuit is the likely culprit.
Do not keep resetting the RCD and trying the shower again. Each trip means current is going somewhere it should not, and repeatedly forcing it can turn a small fault into a burnt-out switch or a shock risk. Never open the shower cover or remove the RCD.
How an electrician finds the fault
When we carry out electrical fault finding, we isolate the circuit and test it properly rather than guessing. Insulation resistance testing shows whether the shower, cable or switch is leaking to earth, and we check the RCD trips within the correct time. We will also look at the cable size and protective device, because a shower that has been upgraded to a higher kilowatt rating on the original cable is a common hidden problem.
Sometimes the fix is simple, such as a new pull-cord switch or a replacement shower. If the leakage is spread across several circuits on an old board, a consumer unit replacement with individual RCBO protection for each circuit can stop one fault knocking out the whole house.
Electric shower tripping RCD: frequently asked questions
Is it safe to keep using the shower if it only trips now and then?
No. An intermittent trip usually means a fault that is getting worse. Stop using the shower and have it checked.
Should I just buy a new shower?
Not before the circuit is tested. If the fault is in the cable or switch, a new shower will trip in the same way. A more powerful shower may also need a larger cable.
Can a plumber fix it?
A plumber can deal with leaks and pipework, but any work on the shower circuit, switch or consumer unit should be done by a registered electrician. Work on a new or altered circuit in a bathroom is notifiable under Part P of the Building Regulations.
We help homeowners with domestic electrical faults across the county, from our base in Woodhall Spa to Horncastle, Lincoln and beyond.